Tektronix P6054A Passive Voltage Probe

Back to Tek Probes Summary Page
BAMA P6054A Free Manual Download Site

e-Bay Sample Prices
Quick Specifications / Photos
Compatibility
Characteristics
Detailed Specifications

ORIGINAL COSTS
Tektronix Catalog Cost
$ ?
e-Bay Sample Prices

QUICK SPECS / PHOTOS
  • Bandwidth : DC to 150 MHz
  • Attenuation : 10X
  • Input Resistance : 10 MΩ
  • Input Capacitance : approx. 9.5pF
  • Scope Input Resis : 1 MΩ
  • Compensation Range : 15pF to 24pF
  • Readout Pin : No
  • Ground Ref : Yes
  • ID Button : No
  • Max Rated Voltage : 500 V (DC + Peak AC)
  • COMPATIBILITY

    453, 453A, 454, 454A, 10A2A

    CHARACTISTICS

    The P6054A Probe is a miniature, passive, fast-rise, 10X attenuation probe designed primarily for use with Tektronix oscilloscopes, such as 453, 453A, 454, 454A, and the 10A2A Plug-In Unit. The probe can be compensated for use with other oscilloscopes or plug-in units that have an input capacitance of 15 to 24 pF (paralleled by 1 MΩ).

    The probe consists of a small-diameter probe body assembly (especially useful in compact circuitry), a 3.5-foot, 6-foot, or 9-foot cable, and a compensating box with a BNC connector.

    A ground reference pushbutton on the body of the probe permits the user to obtain a ground reference or to determine which trace of a multitrace display includes the signal from the P6054A Probe.

    The compensating box houses a compensation network that provides optimum transient response when the probe is used with wideband oxcilloscopes. The probe can be low-frequency compensated to match the input of the associated instrument by adjusting the variable capacitor through the hole in the compensating box housing. Internal calibration adjustments provide high-frequency compensation. A snap-on cover gives access to the internal adjustments.

    (excerpts from P6054A Instruction Manual 010-6054-13)

    SPECIFICATIONS
    Electrical
    Attenuation :10X within 3% (including 1 MΩ, ±2% amplifier input)
    Input Resistance :10 MΩ within 2% (includes input R of amplifier).
    Input Capacitance : 3.5-foot cable : 9.5 pF, ±0.5 pF
    6-foot cable : 12.5 pF, ±0.5 pF
    9-foot cable : 13.5 pF, ±0.5 pF
    Compensation Range :15 pF or less to at least 24 pF.
    Bandwidth (-3 dB) :3.5-foot and 6-foot cables, @150 MHz
    9-foot cable, @115 MHz.
    Maximum Input Voltage :500 V (DC + peak AC), derated with frequency.
    Physical
    Net Weight :With 3.5-foot cable, @5 ounces (141.8 grams)
    With 6-foot cable, @5.25 ounces (148.8 grams)
    With 9-foot cable, @5.5 ounces (155.9 grams)
    Dimension:
    PROBE BODY : @3.7 inches (9.4 cm), length; @0.45 inch (1.1 cm), maximum outside diameter.
    CABLE: @3.5 feet (1.1 meter), @6 feet (1.8 meters), or @9 feet (2.7 meters) between strain relief bases.
    COMPENSATION BOX: Length, @1.7 inches (4.3 cm); Width, @0.6 inch (1.5 cm); Height, @1.2 inches (3.0 cm).
    Environmental

    Probe will operate within specifications over the following ranges:
    Temperature : -15° to +75°C.
    Altitude : To 15,000 feet.

    (excerpts from P6054A Instruction Manual 010-6054-13)

    SAMPLES OF E-BAY PRICES
    Tektronix Catalog CostLow BidHigh Bidaverage
    $ ? ...
    $32.00 3/7/03 #2512519822 erlyman (new in bag - 2 bids $30 start)