Tektronix P6046

Back to Tek Probes Summary Page
e-Bay Sample Prices
Quick Specifications / Photos
Compatibility
Characteristics
Detailed Specifications

ORIGINAL COSTS
Tektronix Catalog CostLow BidHigh Bidaverage
$425 w/o Amp, $725 w/ Amp (1969)
$470 w/o Amp, $850 w/ Amp (1973)
$570 w/o Amp, $1100 w/ Amp (1977)
$775 w/o Amp, $1490 w/ Amp (1982)
$825 w/o Amp, $1750 w/ Amp (1985)
$895 w/o Amp, $1895 w/ Amp(1989)
...
$41.00 7/24/01 #1617980200 jsrlab
$36.00 8/13/01 #1624618207 pactest
$101.00 8/14/01 #1625017364 pactest
$76.99 12/10/02 #1923359315 computerliquidationcenter
$69.95 (+$20 ship) 8/14/07 #110156902654 mou_enterprises_inc (1 bid) (like new w/ box & accessories)
$19.72 (+~$16 ship) 1/23/08 #320208531813 testgearnation (2 bids $9.99 start) (accepts input and output - w/amp and p.s.)
$19.38 (+$10 ship) 5/31/09 #350206125896 wma100 (5 bids $0.99 start) (probe with amp & P.S.-untested)

QUICK SPECS / PHOTOS
  • 100MHz
  • 1,10X
  • Compensation Range:
  • Readout :

    Use with 1A5

    Item Specifications

    The P6046 Differential Probe and P6046 Amplifier Unit provide unique measurement capabilities with all oscilloscopes. The differential-signal processing takes place in the probe itself, resulting in high common-mode signal rejection at higher frequencies. Differential probe-tip signal processing minimizes the measurement errors caused by differences in probes, cable lengths, and input attenuators.
    Active Differential Probe System
    Characteristics
  • CMRR - With deflection factors of 1 to 20 mV/div: at least 10,000: 1 at 50 kHz, 5000: 1 at 1 MHz, and 1000: 1 at 50 MHz (DC coupled).
  • Common Mode Linear Dynamic Range - 5 V, 50 V with 10x attenuator
  • Bandwidth - DC to 100 MHz (-3 dB)
  • Rise Time - 3.5 ns or less
  • Deflection Factor Range - 1 to 200 mV/div in 8 calibrated steps, 1-2-5 sequence (with an oscilloscope deflection factor of 10 mV/div). Input RC 1 M ohm paralleled by 10 pF or less.
  • Input Coupling - AC or DC, selected by a switch on the probe. Low frequency response AC-coupled is -3 dB at 20 Hz, 2 Hz with 10x attenuator.
  • Displayed Noise - Typically 450 mV or less.
  • Maximum Input Voltage - 25 V (DC peak AC), 250 V with 10x attenuation, derated with frequency.
  • Output Impedance - 50 ohms through a BNC-connector. 50 ohm termination supplied with amplifier for use with 1 M ohm systems.
  • Probe Cable - 6 ft. long, terminated with special nine-pin connector.
    COMPATIBILITY
    CHARACTISTICS
    SPECIFICATIONS


    SAMPLES OF E-BAY PRICES