Tektronix P6022 AC Current Probe 50 Turns

Back to Tek Probes Summary Page
This manual was available from Tektronix for Download

e-Bay Sample Prices
Quick Specifications / Photos
Compatibility
Characteristics
Detailed Specifications

ORIGINAL COSTS
Tektronix Catalog CostLow BidHigh Bidaverage
$150 (passive term), $325 (w/ 134 Amp) (1969-new)
$170 (passive term), $357 (w/ 134 Amp) (1973)
$205 (passive term), $555 (w/ 134 Amp) (1977)
$325 (passive term), $865 (w/ 134 Amp) (1982)
$430 (passive term), $1055 (w/ 134 Amp) (1985)
$495 (passive term), $1165 (w/ 134 Amp) (1989)
$675 (1998)
$1300 (passive term) (1/2008)
...
$35.00 7/28/01 #1620611614 teoutlet(tucker)
$102.50 8/8/01 #1622924372 outback6 (with termination)
$100.00 8/16/01 #1625720815 outback6 (with termination)
$115.50 3/28/05 #7503361222 rasput (9 bids $9 start) (used, untested, no termination)
$158.38 (+ $?? ship) 1/2/08 #220187324163 bad69rs (17 bids $39.95 start) (with termination, manual)
$152.50 (+~$13 ship) 1/23/08 #290199629986 etech4sale (8 bids $10 start) (with termination - used, untested)
$255.00 (+~$10 ship) 4/21/09 #150338488554 eaw_old_cdp (3 bids $190 start) (with termination - tested,fully functional w/ original manual)

QUICK SPECS / PHOTOS
  • Bandwidth : 935 Hz to 120 MHz (10 mA/mV)
    8.5 kHz to 100 MHz (1 mA/mV)
  • Sensitivity : 1 mA or 10 mA for each mV at oscilloscope input, selected by termination sensitivity control.
  • Insertion Impedance : 0.03Ω or less at 1 MHz
  • Maximum Conductor Diameter : 0.141"
  • Readout Pin : NO
  • Ground Ref : n/a
  • ID Button : NO
  • Max Rated Current : 6A(p-p) RMS
  • Max Rated Voltage : 300 VRMS
  • Cable Length : 5 ft or 9 ft
  • Net Weight : 2.5 oz (w/5 ft cable)
    3.2 oz (w/9 ft cable)
    1.7 oz for Termination
  • Scope Compatibility : Most General Purpose


  • The P6022 current probe converts an alternating current waveform to a voltage that can be displayed and measured on an oscilloscope display. It provides accurate current measurements over a wide range of frequencies, and allows you to measure current without breaking the circuit.

    The P6022 probe is compatible with general purpose oscilloscopes having a 1 MΩ input impedance. The P6022 probe comes with a passive termination that matches oscilloscope and probe impedance, optimizes the probe performance, and provides two sensitivity settings.

    In the standard configuration, the P6022 probe comes with a 5-foot cable and termination. The following option is also available.

    Option 03 - 9-foot cable with termination

    (above excerpt from Tektronix® Products Instruction Manual 070-0948-03 for P6022)

    You can use the 134 Amplifier for instruments having a 50 ohm input.

  • Shielded Probe Heads
  • Split Core
  • Shielded probe heads are not grounded when the slides are in their open positions, eliminating accidental grounding of the circuit under test.
    COMPATIBILITY
    CHARACTISTICS
    SPECIFICATIONS


    SAMPLES OF E-BAY PRICES